Acroloop Motion Control Systems — 00:D0:5B (MA-L)
Summary
- // what this is
- Acroloop Motion Control Systems is registered to MAC prefix
00:D0:5Bin the IEEE OUI database. When a device's MAC address begins with00:D0:5B, that block was registered by Acroloop Motion Control Systems — the OUI identifies the maker of the network hardware, which is not always the brand on the device. Acroloop Motion Control Systems was acquired; the registration remains on record with IEEE. - // analyst note
- 00:D0:5B on a globally-administered address identifies genuine Acroloop/Parker-Acroloop motion-control hardware; these are embedded industrial controllers, not consumer IT gear.
About this vendor.
Acroloop Motion Control Systems, Inc. holds a single IEEE MA-L block, 00:D0:5B, registered to "ACROLOOP MOTION CONTROL" out of Chaska, Minnesota. The registry name reads short because the raw the IEEE MA-L registry row splits mid-name — the organization line carries "ACROLOOP MOTION CONTROL" while the trailing "SYSTEMS CHASKA MN US 55318" lands in the address field, a common IEEE CSV formatting quirk rather than two separate facts; the full corporate name is Acroloop Motion Control Systems. Behind this lone prefix sits a real, well-documented industrial manufacturer, not a bare single-OUI shell. Acroloop built the ACR series of multi-axis motion controllers — the ACR1500, ACR2000, ACR8000/8010/8020, ACR8100/8200 lineage — plus OEM software such as AcroMill NT and the AcroLIB programming API, used in CNC and industrial-automation machinery. The company was acquired by Parker Hannifin Corporation in 2001 and folded into Parker's Compumotor Division; the product line continued under the "Parker Acroloop" brand and later evolved into Parker's ACR9000-series controllers. Legacy manuals and catalogs remain hosted on parkermotion.com and divapps.parker.com, and specific model numbers still surface on independent industrial-surplus and repair-vendor listings. Because these are embedded/industrial controller products rather than consumer IT gear, the 00:D0:5B OUI would appear on networked motion-control hardware rather than general networking equipment. IEEE publishes no assignment date for OUI blocks, so no registration date is recorded here.
- IEEE assignment
- 00:D0:5B → "ACROLOOP MOTION CONTROL", Chaska, MN, US [Confirmed] — IEEE MA-L (raw row
MA-L,00D05B,ACROLOOP MOTION CONTROL,SYSTEMS CHASKA MN US 55318) - Registry / block size
- MA-L (24-bit OUI); single prefix (00:D0:5B) only [Confirmed] — the IEEE MA-L registry. No match in the IEEE MA-M registry (MA-M) or the IEEE MA-S registry (MA-S).
- Registered company name
- Acroloop Motion Control Systems (registry field truncates to "ACROLOOP MOTION CONTROL"; "SYSTEMS" carried into the address line by an IEEE CSV column-split artifact) [Confirmed] — the IEEE MA-L registry, https://controlrepair.com/product/manufacturer/acroloop-motion-control-systems-1808
- HQ / country
- Chaska, MN 55318, US (registry address) [Confirmed] — the IEEE MA-L registry. One independent web source additionally gives a street address of 3650 Chestnut Street North, Chaska, MN 55318 [Likely] — https://controlrepair.com/product/manufacturer/acroloop-motion-control-systems-1808
- Company status
- acquired — Acroloop Motion Control Systems, Inc. was acquired by Parker Hannifin Corporation in 2001 and folded into the Compumotor Division; product line continued as "Parker Acroloop," later evolving into Parker's ACR9000-series controllers [Likely] — https://motionusa.com/manufacturer/parker-automation, https://divapps.parker.com/divapps/emn/prior_version_compumotor/cat/english/acroloop/AcroloopCat_Intro.pdf
- Device types
- industrial multi-axis motion controllers — ACR series (ACR1000/1500/2000/8000/8010/8020/8100/8200) and OEM software (AcroMill NT, AcroLIB API) for CNC and industrial automation [Confirmed] — https://www.parkermotion.com/literature/precision_cd/CD-EM/compumotor/cat/english/ACR_series.pdf, https://www.parkermotion.com/manuals/Acroloop/AcroMILL_OEM_Supplement.pdf
- Notable products
- ACR-series motion controllers; AcroLIB programming API; AcroMill NT [Confirmed] — https://www.parkermotion.com/manuals/Acroloop/AcroLib304Manual.pdf, https://www.artisantg.com/PLC/63431-4/Parker-Acroloop-ACR2000-Motion-Controller
- Registration date
- Unknown — IEEE publishes NO assignment/registration date for OUI blocks (the IEEE MA-L registry columns are only Registry, Assignment, Organization Name, Organization Address). Any "date registered" on third-party MAC-lookup tools is a database artifact, not an IEEE fact. (A "Oct 7, 2002" date on the AcroLIB manual is a document-effective date, unrelated to OUI registration, and is not used here.)[Confirmed] — the IEEE MA-L registry
- IANA reference
- N/A — not applicable to OUI/MAC vendor registry data; leave blank [Confirmed]
- Security / abuse context
- Unknown / no findings — no CVEs, advisories, or threat-intel reports surfaced for this OUI or the ACR-series controllers. Expected null for legacy industrial motion hardware; sourced absence, not a confirmed clean bill of health. [Unknown]
- Analyst note
- single-OUI vendor, but backed by a genuine, checkable device catalog and post-acquisition corporate lineage — the opposite of a bare unverifiable registration.